Error Code E IS
Defect of ice-room sensor or ice maker sensor — short-circuit or disconnection
Moderate
Address soon - your appliance may not work properly
Also displayed as: E IS
How to Fix
- 1
Step 1: Check connector between Main PCB and sensor. If disconnected or loose, reconnect or repair connector.
- 2
Step 2: Measure sensor resistance at CON3 10th Pin ~ 9th Pin. If 0 ohm (short), replace sensor.
- 3
Step 3: If OL/infinite (open), proceed to step 6.
- 4
Step 4: Compare resistance to temperature-resistance table. If within spec, explain to customer — unit is normal.
- 5
Step 5: If out of spec, replace the sensor.
- 6
Step 6: Check sensor body connection. If normal, replace refrigerator PCB.
- 7
Step 7: If connection abnormal, reconnect or repair connector.
Other Error Codes for LRYXC2606B
Defect of ice maker kit — malfunction of in-door ice maker motor
Defect of flow meter or lack of water supply — malfunction of flow meter. Check connection of flow meter and water supply.
Defect of freezer defrost sensor — short-circuit or disconnection of defrost sensor
PSD (Position Sensor Device) sensor error — malfunction of PSD sensor
Defect of freezer craft ice maker sensor — short-circuit or disconnection of craft ice maker sensor
Defect of Mini Cubed ice maker kit — malfunction of Mini Cubed ice maker motor
Defect of refrigerator sensor — short-circuit or disconnection of refrigerator sensor
Defect of freezer sensor — short-circuit or disconnection of freezer sensor